Customer:
Ministry of Water Resources and Irrigation, Mechanical and Electrical Department (MED)
Place:
Cairo, Egypt
Year:
2015
Description of works:
El-Thawra 2 pumping station
- no. 5 electric-pumps MISA E3P 210 FF, each with capacity 3200 l/s, head 3,30 m, power 150 kW
- spare parts
El-Thawra 4 pumping station
- no. 5 electric-pumps MISA E3P 185 FF, each with capacity 2100 l/s, head 5,60 m, power 165 kW
- spare parts
Nominal characteristics
Total capacity: 26.500 l/s - 26,5 mc/s
Total power: 1575 kW
Particular notes
Complete overhaul of the El-Thawra 2 & 4 pumping stations for irrigation service with water withdrawal from the Nile.
The study also provides for fluid dynamics analysis on the old civil works, in order to avoid the formation of surface vortices.